Будь ласка, використовуйте цей ідентифікатор, щоб цитувати або посилатися на цей матеріал:
http://elartu.tntu.edu.ua/handle/lib/54171
| Назва: | Water temperature measurement in an automated terrarium using a Pt1000 sensor |
| Автори: | Zdorenko, Valerii Basaliuk, Maksym |
| Приналежність: | National Technical University of Ukraine «Igor Sikorsky Kyiv Polytechnic Institute», Kyiv, Ukraine |
| Бібліографічний опис: | Zdorenko V. Water temperature measurement in an automated terrarium using a Pt1000 sensor / Valerii Zdorenko, Maksym Basaliuk // Scientific Journal of TNTU. — Tern. : TNTU, 2026. — Vol 122. — No 2. — P. 33–42. |
| Бібліографічне посилання: | Zdorenko V., Basaliuk M. Water temperature measurement in an automated terrarium using a Pt1000 sensor // Scientific Journal of TNTU, Ternopil. 2026. Vol 122. No 2. P. 33–42. |
| Bibliographic citation (APA): | Zdorenko, V., & Basaliuk, M. (2026). Water temperature measurement in an automated terrarium using a Pt1000 sensor. Scientific Journal of the Ternopil National Technical University, 122(2), 33-42. TNTU.. |
| Bibliographic citation (CHICAGO): | Zdorenko V., Basaliuk M. (2026) Water temperature measurement in an automated terrarium using a Pt1000 sensor. Scientific Journal of the Ternopil National Technical University (Tern.), vol. 122, no 2, pp. 33-42. |
| Є частиною видання: | Вісник Тернопільського національного технічного університету, 2 (122), 2026 Scientific Journal of the Ternopil National Technical University, 2 (122), 2026 |
| Журнал/збірник: | Вісник Тернопільського національного технічного університету |
| Випуск/№ : | 2 |
| Том: | 122 |
| Дата публікації: | 26-тра-2026 |
| Дата подання: | 13-лют-2026 |
| Дата внесення: | 13-жов-2026 |
| Видавництво: | ТНТУ TNTU |
| Місце видання, проведення: | Тернопіль Ternopil |
| DOI: | https://doi.org/10.35784/ visnyk_tntu2026.02.033 |
| Теми: | Pt1000 Callendar–Van Dusen terrarium temperature measurement RTD thermal inertia automated system |
| Кількість сторінок: | 10 |
| Діапазон сторінок: | 33-42 |
| Початкова сторінка: | 33 |
| Кінцева сторінка: | 42 |
| Короткий огляд (реферат): | The article considers the application of a platinum resistance thermometer Pt1000 for accurate measurement of water temperature in an automated terrarium. A mathematical model of the resistance-temperature dependence R(T) based on the Callendar–Van Dusen equations is presented. The static and dynamic characteristics of the sensor are analyzed, and the influence of lead wire resistance and measurement channel noise is evaluated. An experiment was conducted to investigate the response of the Pt1000 sensor to a rapid temperature change in a water environment. The obtained curves demonstrate a fast initial temperature jump in the sensor contact zone with hot water, followed by a transient mixing of layers with damped oscillations and gradual establishment of thermal equilibrium. The experimental results confirm a first-order dynamic model with an effective thermal time constant τ and are consistent with analytical estimates of thermal inertia. The obtained dependencies make it possible to improve calibration accuracy and optimize digital filtering algorithms in terrarium microclimate control systems. |
| URI (Уніфікований ідентифікатор ресурсу): | http://elartu.tntu.edu.ua/handle/lib/54171 |
| ISSN: | 2522-4433 |
| Власник авторського права: | © Тернопільський національний технічний університет імені Івана Пулюя, 2026 |
| URL-посилання пов’язаного матеріалу: | https://doi.org/10.3390/s25196134 https://doi.org/10.33108/visnyk_tntu2024.02.011 https://doi.org/10.3390/s20092742 https://doi.org/10.3390/s22114176 https://doi.org/10.3390/s24247991 https://doi.org/10.3390/s24237689 https://doi.org/10.1109/TIM.2022.3145674 https://doi.org/10.2478/msr-2021-0001 https://doi.org/10.3390/jsan9020015 https://doi.org/10.3390/electronics14122393 https://doi.org/10.23939/istcmtm2025.03.043 https://doi.org/10.1109/JSEN.2018.2872215 https://doi.org/10.33108/visnyk_tntu2023.01.090 |
| References: | 1. Bicamumakuba E., Kibet K., Musyoka J., Kimwele M. (2025) Multi-sensor monitoring and intelligent control for smart greenhouse environment management, Sensors, 25 (19), article 6134. https://doi.org/10.3390/s25196134. 2. Korenivska O., Melnyk V., Tymchyshyn V. (2023). IoT monitoring system for microclimate parameters in classrooms, in: CEUR Workshop Proceedings, pp. 45–52. 3. Voichyshyn Y. (2024) Study of microclimate indicators of a bus driver’s workplace in the warm season, Scientific Journal of TNTU, 114 (2), pp. 11–19. https://doi.org/10.33108/visnyk_tntu2024.02.011. 4. International Electrotechnical Commission, IEC 60751: Industrial Platinum Resistance Thermometers and Platinum Temperature Sensors, IEC, Geneva, 2022. 5. Bureau International des Poids et Mesures, Guide to the Realization of the ITS-90: Standard Platinum Resistance Thermometry (SPRT), BIPM, Paris, 2021. 6. Li W., Xiong S., Zhou X. (2020) Lead-wire-resistance compensation technique using a single Zener diode for two-wire RTDs, Sensors, 20 (9), article 2742. https://doi.org/10.3390/s20092742. 7. Rerkratn A., Tangsrirat W., Surakampontorn W. (2022) A procedure for precise determination and compensation of lead-wire resistance for RTD sensors. Sensors, 22 (11), article 4176. https://doi.org/10.3390/s22114176. 8. Li J., Zhang Y., Wang H. (2024) Method for correcting error due to self-heating of resistance temperature detectors. Sensors, 24 (24), article 7991. https://doi.org/10.3390/s24247991. 9. Miczulski W. (2024) Intelligent transducer for temperature measurement with two-wire or three- wire platinum RTD. Sensors, 24 (23), article 7689. https://doi.org/10.3390/s24237689. 10. Reverter F. (2022) A microcontroller-based interface circuit for three-wire connected resistive sensors. IEEE Transactions on Instrumentation and Measurement, 71, article 2006704. https://doi.org/10.1109/TIM.2022.3145674. 11. Jovanović J., Popović R., Živanov M. (2021)Mixed-mode method used for Pt100 static transfer function linearization. Measurement Science Review, 21, pp. 1–8. https://doi.org/10.2478/msr-2021-0001. 12. Chen A., Huang Y., Lin S. (2020) A software improvement technique for platinum resistance thermometers. Journal of Sensor and Actuator Networks, 9 (2), article 15. https://doi.org/10.3390/jsan9020015. 13. Puentes-Conde G., Reverter F., Gasulla M. (2025) Direct interface circuits for resistive, capacitive, and inductive sensors: A review, Electronics, 14 (12), article 2393. https://doi.org/10.3390/electronics14122393. 14. Zdorenko V., Basaliuk M., Moroz-Parkhomenko O. (2025) Information-measuring system for microclimate control in the exhibition modules of the Kyiv Zoo. Measuring Equipment and Metrology, 86 (3), pp. 43–47. https://doi.org/10.23939/istcmtm2025.03.043. 15. Physikalisch-Technische Bundesanstalt, DKD-R 5-1 Calibration of Resistance Thermometers, PTB, Braunschweig, 2023. 16. Shen A., Zhao Y., Liu X. (2018) Direct write fabrication of platinum-based thick-film resistive temperature detectors. IEEE Sensors Journal, 18 (22), pp. 9105–9113. https://doi.org/10.1109/JSEN.2018.2872215. 17 Voichyshyn Y., Holenko K., Horbay O., Honchar V. (2023) Methodology of analytical research of microclimate using ANSYS Fluent. Scientific Journal of TNTU, 109 (1), pp. 90–98. https://doi.org/10.33108/visnyk_tntu2023.01.090. |
| Тип вмісту: | Article |
| Показва се в Колекции: | Вісник ТНТУ, 2026, № 2 (122) |
Файлове в Този Публикация:
| Файл | Описание | Размер | Формат | |
|---|---|---|---|---|
| TNTUSJ_2026v122n2_Zdorenko_V-Water_temperature_measurement_33-42.pdf | 4,05 MB | Adobe PDF | Переглянути/відкрити | |
| TNTUSJ_2026v122n2_Zdorenko_V-Water_temperature_measurement_33-42__COVER.png | 1,05 MB | image/png | Переглянути/відкрити |
Усі матеріали в архіві електронних ресурсів захищені авторським правом, всі права збережені.