Använd denna länk för att citera eller länka till detta dokument: http://elartu.tntu.edu.ua/handle/lib/54171

Fullständig post
DC fältVärdeSpråk
dc.contributor.authorZdorenko, Valerii
dc.contributor.authorBasaliuk, Maksym
dc.date.accessioned2026-10-13T08:48:20Z-
dc.date.available2026-10-13T08:48:20Z-
dc.date.created2026-05-26
dc.date.issued2026-05-26
dc.date.submitted2026-02-13
dc.identifier.citationZdorenko V. Water temperature measurement in an automated terrarium using a Pt1000 sensor / Valerii Zdorenko, Maksym Basaliuk // Scientific Journal of TNTU. — Tern. : TNTU, 2026. — Vol 122. — No 2. — P. 33–42.
dc.identifier.issn2522-4433
dc.identifier.urihttp://elartu.tntu.edu.ua/handle/lib/54171-
dc.description.abstractThe article considers the application of a platinum resistance thermometer Pt1000 for accurate measurement of water temperature in an automated terrarium. A mathematical model of the resistance-temperature dependence R(T) based on the Callendar–Van Dusen equations is presented. The static and dynamic characteristics of the sensor are analyzed, and the influence of lead wire resistance and measurement channel noise is evaluated. An experiment was conducted to investigate the response of the Pt1000 sensor to a rapid temperature change in a water environment. The obtained curves demonstrate a fast initial temperature jump in the sensor contact zone with hot water, followed by a transient mixing of layers with damped oscillations and gradual establishment of thermal equilibrium. The experimental results confirm a first-order dynamic model with an effective thermal time constant τ and are consistent with analytical estimates of thermal inertia. The obtained dependencies make it possible to improve calibration accuracy and optimize digital filtering algorithms in terrarium microclimate control systems.
dc.format.extent33-42
dc.language.isoen
dc.publisherТНТУ
dc.publisherTNTU
dc.relation.ispartofВісник Тернопільського національного технічного університету, 2 (122), 2026
dc.relation.ispartofScientific Journal of the Ternopil National Technical University, 2 (122), 2026
dc.relation.urihttps://doi.org/10.3390/s25196134
dc.relation.urihttps://doi.org/10.33108/visnyk_tntu2024.02.011
dc.relation.urihttps://doi.org/10.3390/s20092742
dc.relation.urihttps://doi.org/10.3390/s22114176
dc.relation.urihttps://doi.org/10.3390/s24247991
dc.relation.urihttps://doi.org/10.3390/s24237689
dc.relation.urihttps://doi.org/10.1109/TIM.2022.3145674
dc.relation.urihttps://doi.org/10.2478/msr-2021-0001
dc.relation.urihttps://doi.org/10.3390/jsan9020015
dc.relation.urihttps://doi.org/10.3390/electronics14122393
dc.relation.urihttps://doi.org/10.23939/istcmtm2025.03.043
dc.relation.urihttps://doi.org/10.1109/JSEN.2018.2872215
dc.relation.urihttps://doi.org/10.33108/visnyk_tntu2023.01.090
dc.subjectPt1000
dc.subjectCallendar–Van Dusen
dc.subjectterrarium
dc.subjecttemperature measurement
dc.subjectRTD
dc.subjectthermal inertia
dc.subjectautomated system
dc.titleWater temperature measurement in an automated terrarium using a Pt1000 sensor
dc.typeArticle
dc.rights.holder© Тернопільський національний технічний університет імені Івана Пулюя, 2026
dc.coverage.placenameТернопіль
dc.coverage.placenameTernopil
dc.format.pages10
dc.relation.referencesen1. Bicamumakuba E., Kibet K., Musyoka J., Kimwele M. (2025) Multi-sensor monitoring and intelligent control for smart greenhouse environment management, Sensors, 25 (19), article 6134. https://doi.org/10.3390/s25196134.
dc.relation.referencesen2. Korenivska O., Melnyk V., Tymchyshyn V. (2023). IoT monitoring system for microclimate parameters in classrooms, in: CEUR Workshop Proceedings, pp. 45–52.
dc.relation.referencesen3. Voichyshyn Y. (2024) Study of microclimate indicators of a bus driver’s workplace in the warm season, Scientific Journal of TNTU, 114 (2), pp. 11–19. https://doi.org/10.33108/visnyk_tntu2024.02.011.
dc.relation.referencesen4. International Electrotechnical Commission, IEC 60751: Industrial Platinum Resistance Thermometers and Platinum Temperature Sensors, IEC, Geneva, 2022.
dc.relation.referencesen5. Bureau International des Poids et Mesures, Guide to the Realization of the ITS-90: Standard Platinum Resistance Thermometry (SPRT), BIPM, Paris, 2021.
dc.relation.referencesen6. Li W., Xiong S., Zhou X. (2020) Lead-wire-resistance compensation technique using a single Zener diode for two-wire RTDs, Sensors, 20 (9), article 2742. https://doi.org/10.3390/s20092742.
dc.relation.referencesen7. Rerkratn A., Tangsrirat W., Surakampontorn W. (2022) A procedure for precise determination and compensation of lead-wire resistance for RTD sensors. Sensors, 22 (11), article 4176. https://doi.org/10.3390/s22114176.
dc.relation.referencesen8. Li J., Zhang Y., Wang H. (2024) Method for correcting error due to self-heating of resistance temperature detectors. Sensors, 24 (24), article 7991. https://doi.org/10.3390/s24247991.
dc.relation.referencesen9. Miczulski W. (2024) Intelligent transducer for temperature measurement with two-wire or three- wire platinum RTD. Sensors, 24 (23), article 7689. https://doi.org/10.3390/s24237689.
dc.relation.referencesen10. Reverter F. (2022) A microcontroller-based interface circuit for three-wire connected resistive sensors. IEEE Transactions on Instrumentation and Measurement, 71, article 2006704. https://doi.org/10.1109/TIM.2022.3145674.
dc.relation.referencesen11. Jovanović J., Popović R., Živanov M. (2021)Mixed-mode method used for Pt100 static transfer function linearization. Measurement Science Review, 21, pp. 1–8. https://doi.org/10.2478/msr-2021-0001.
dc.relation.referencesen12. Chen A., Huang Y., Lin S. (2020) A software improvement technique for platinum resistance thermometers. Journal of Sensor and Actuator Networks, 9 (2), article 15. https://doi.org/10.3390/jsan9020015.
dc.relation.referencesen13. Puentes-Conde G., Reverter F., Gasulla M. (2025) Direct interface circuits for resistive, capacitive, and inductive sensors: A review, Electronics, 14 (12), article 2393. https://doi.org/10.3390/electronics14122393.
dc.relation.referencesen14. Zdorenko V., Basaliuk M., Moroz-Parkhomenko O. (2025) Information-measuring system for microclimate control in the exhibition modules of the Kyiv Zoo. Measuring Equipment and Metrology, 86 (3), pp. 43–47. https://doi.org/10.23939/istcmtm2025.03.043.
dc.relation.referencesen15. Physikalisch-Technische Bundesanstalt, DKD-R 5-1 Calibration of Resistance Thermometers, PTB, Braunschweig, 2023.
dc.relation.referencesen16. Shen A., Zhao Y., Liu X. (2018) Direct write fabrication of platinum-based thick-film resistive temperature detectors. IEEE Sensors Journal, 18 (22), pp. 9105–9113. https://doi.org/10.1109/JSEN.2018.2872215.
dc.relation.referencesen17 Voichyshyn Y., Holenko K., Horbay O., Honchar V. (2023) Methodology of analytical research of microclimate using ANSYS Fluent. Scientific Journal of TNTU, 109 (1), pp. 90–98. https://doi.org/10.33108/visnyk_tntu2023.01.090.
dc.identifier.doihttps://doi.org/10.35784/ visnyk_tntu2026.02.033
dc.contributor.affiliationNational Technical University of Ukraine
dc.contributor.affiliation«Igor Sikorsky Kyiv Polytechnic Institute», Kyiv, Ukraine
dc.citation.journalTitleВісник Тернопільського національного технічного університету
dc.citation.volume122
dc.citation.issue2
dc.citation.spage33
dc.citation.epage42
dc.identifier.citation2015Zdorenko V., Basaliuk M. Water temperature measurement in an automated terrarium using a Pt1000 sensor // Scientific Journal of TNTU, Ternopil. 2026. Vol 122. No 2. P. 33–42.
dc.identifier.citationenAPAZdorenko, V., & Basaliuk, M. (2026). Water temperature measurement in an automated terrarium using a Pt1000 sensor. Scientific Journal of the Ternopil National Technical University, 122(2), 33-42. TNTU..
dc.identifier.citationenCHICAGOZdorenko V., Basaliuk M. (2026) Water temperature measurement in an automated terrarium using a Pt1000 sensor. Scientific Journal of the Ternopil National Technical University (Tern.), vol. 122, no 2, pp. 33-42.
Samling:Вісник ТНТУ, 2026, № 2 (122)



Materialet i DSpace är upphovsrättsligt skyddat och får ej användas i kommersiellt syfte!