Link lub cytat. http://elartu.tntu.edu.ua/handle/lib/36942

Titulua: Ensuring high high-precision testing of implants in the regulation of intra intra-eye pressure
Egilea: Tkachuk, Roman
Tkachuk, Andriy
Stadnik, Diana
Yanenko, Oleksiy
Affiliation: Ternopil Ivan Puluj National Technical University, Rus’ka str. 56, 46001, Ternopil, Ukraine
Igor Sikorsky Kyiv Polytechnic Institute
Bibliographic description (Ukraine): Ensuring high high-precision testing of implants in the regulation of intra intra-eye pressure / Roman Tkachuk, Andriy Tkachuk, Diana Stadnik, Oleksiy Yanenko // ICAAEIT 2021, 15-17 December 2021. — Tern. : TNTU, Zhytomyr «Publishing house „Book-Druk“» LLC, 2021. — P. 157–161. — (Biomedical engineering).
Bibliographic description (International): Tkachuk R., Tkachuk A., Stadnik D., Yanenko O. (2021) Ensuring high high-precision testing of implants in the regulation of intra intra-eye pressure. ICAAEIT 2021 (Tern., 15-17 December 2021), pp. 157-161.
Is part of: Proceedings of the International Conference „Advanced applied energy and information technologies 2021”, 2021
Gordailuaren-data: 15-Dec-2021
Date of entry: 28-Dec-2021
Argitalpen: TNTU, Zhytomyr «Publishing house „Book-Druk“» LLC
Place of the edition/event: Ternopil
Temporal Coverage: 15-17 December 2021
Gako-hitzak: glaucoma
intraocular fluid
intraocular pressure measurement
implant
automation of blood pressure control process
working range of intraocular pressure (IOP)
Number of pages: 5
Page range: 157-161
Start page: 157
End page: 161
Laburpena: Among the diseases that lead to partial or complete loss of visual function is glaucoma, which is characterized by increased intraocular pressure (IOP) due to changes in the structures of the eye and the human body, which inevitably leads to blindness. According to the WHO in 2020. more than 5 million people suffer from vision loss in glaucoma, which accounts for 13.5% of all cases of blindness in the world. Today this figure in Ukraine reaches more than 200 thousand patients. Visual problems significantly reduce the level of information perception and cause a pathological condition with progressive death of ganglion cell axons, which causes a decrease and complete loss of the visual field. Known methods of glaucoma treatment use drug therapy, laser therapy and surgical implantation of drainage devices. It was found that the main cause of the disease is a decrease in the speed of movement and outflow of intraocular fluid through the trabecular system of the eye, due to a significant increase in pressure. The optimal rate of fluid formation is normally 2-2.5 μl / min., Ie during the day through this natural system of the patient should be released in a controlled manner and about 3 ml. It is obvious that the implantation of drainage devices in glaucoma is performed after previous unsuccessful treatment procedures and is the last chance to preserve the patientʼs vision, provided that the rate of fluid leakage is successfully regulated. Therefore, there is often a need for preoperative individual selection of implants with the necessary parameters.
URI: http://elartu.tntu.edu.ua/handle/lib/36942
ISBN: 978-617-8079-60-4
Copyright owner: © Ternopil Ivan Puluj National Technical University, Ukraine, 2021
URL for reference material: http://www.who.int
References (International): 1. Brigham, K., Vijaya Kumar B.V.K. (2010). Imagined Speech Classification with EEG Signals for Silent Communication: A Preliminary Investigation into Synthetic Telepathy. International Conference on Bioinformatics and Biomedical Engineering, Proceedings of the 4th International Conference. Chengdu, China.
2. [electronic resource] http://www.who.int
3. Choudhari, N.S., Badakere, S.V., Richhariya, A., Harsha S.N.S., Senthil, S., Garudadri, C.S. (2018). Is Ahmed glaucoma valve consistent in performance. Translational Vision Science and Technology, 7 (3):19, 1-8.
4. Tkachuk, R., Tkachuk, A., Yanenko, O. (2020). Automated system of preoperative control of implant parameters for glaucoma treatment, INSTRUMENTATION: State and Prospects, Proceedings of the 1X International Scientific and Technical Conference. Kyiv, Ukraine.
5. Tkachuk, R., Tkachuk, A., Yanenko, O. Implant testing device for regulation of intraocular pressure: Pat. 143236 UA, IPC A 61B 1/00. No. 2019 09764; 12. 09. 2019; bulging 27.07. 2020, Byul.No 14. 4 ths
Content type: Conference Abstract
Bildumetan azaltzen da:International conference „Advanced Applied Energy and Information Technologies 2021“, (ICAAEIT 2021)



DSpaceko itemak copyright bidez babestuta daude, eskubide guztiak gordeta, baldin eta kontrakoa adierazten ez bada.